JRE 1812WS specifications
- Inside dimensions
- 8" H x 16.5" W x 10.5" D (205 x 420 x 270 mm)
- Outside dimensions
- 8.5" H x 18" W x 12" D (250 x 460 x 305 mm)
- Isolation
- −80 dB DC to 1 GHz, −75 dB to 3 GHz, −70 dB to 6 GHz
- Weight
- 18 lbs (8.2 kg)
- Shipping Weight
- 20 lbs (9.1 kg)
- Shipping Dimensions
- 22" x 16" x 13" (560 x 410 x 330 mm)
- RF Absorbing Foam Thickness
- 3/4" (19 mm)
- RF Absorbing Foam Temp Rating
- 90 degrees Celsius, UL 94V-0 flammability rating
- Window Light Transmission
- Greater than 70%
- Window RF Shielding
- Over 70 dB
- LED Illumination
- Approximately 350 lumens (Li-Ion battery powered)
- I/O Plate Size
- 4.5" x 7" (115 x 180 mm), JRE Test "B" size
- Construction
- Rugged welded aluminum
JRE 1812WS overview
When you need to watch and handle a DUT without opening the shielded enclosure, the JRE 1812WS keeps the work visible and within reach. You have your choice of hand entry: conductive sleeves, which let you work with completely free hands and full tactile feel, or legacy shielded glove entry — tell us which way your operators work and we will configure it that way. Battery-powered LED lighting illuminates the test area without using another I/O connection. I recommend this arrangement when repeated observation and hands-in work are part of the sealed test.
- Interior: 8" H x 16.5" W x 10.5" D (205 x 420 x 270 mm) for multiple-device setups.
- Isolation: −80 dB DC to 1 GHz; −75 dB to 3 GHz; −70 dB to 6 GHz.
- Viewing window: over 70 dB shielding with greater than 70% light transmission for direct observation.
- LED illumination: approximately 350 lumens from a rechargeable Li-Ion battery pack.
- Field-changeable B-size I/O plate: 4.5" x 7" (115 x 180 mm) for the required interfaces.
- 3/4" (19 mm) RF absorbing foam reduces reflections and hot-spots around the DUT.
- RF connectors and interface filters excluded from the base enclosure and specified for each wall connection.
At $2,250.00, this purpose-built enclosure is in stock. The window, lighting, and sleeves make the difference when observation and hands-in access matter during a sealed test. Define every signal, data, power, and RF connection before the field-changeable B-size plate is populated.
Go deeper
- Window Option for RF Shielded Test Enclosures Add an RF shielded viewing window to any suitable enclosure — over 70 dB isolation, 70%+ light transmission, and self-powered 350-lumen LED lighting.
- How to Select and Configure an RF Shielded Test Enclosure A practical engineer's guide to sizing an RF test enclosure, configuring I/O plates, choosing filtered data interfaces, power, thermal, and antennas.
- Keeping Your Cool: Heat, Vents, Fans and Airflow in an RF Shielded Test Enclosure Why RF shielded chambers heat up, how to measure real device wattage instead of the label, and how much airflow it takes to hold your temperature rise.
- Mounting Devices Inside an RF Shielded Test Enclosure How to hold your DUT inside a JRE chamber for repeatable RF tests: the removable ABS floor, why plastic not metal, antenna placement and wall drilling.
Enclosures nearest the JRE 1812WS
Tell us what connections your device needs.
Tell us what connections you need to your device under test — USB, Ethernet, RS-232, RF connectors, etc. We'll spec it out with you. No cart, no checkout: you send an inquiry and we quote it.
Ask an Engineer